- Right hand with the E2 interface The E2R mirrors the left-hand E2L and carries EtherCAT plus RS-485 with 1 kHz real-time communication.
- A force sensor on every actuator Each of the six micro linear servo actuators reports force at 0.1 N resolution, so every finger can stop at a set force.
- Three grip control modes Speed-force protection, force closed-loop and impedance control can be set finger by finger.
- Rigid metal frame at 620 g An all-metal integrated skeleton with internal wiring keeps the hand at 620 g, 183.3 mm long and 79.1 mm across the palm.
- 15 N fingertips, 30 kg passive load Fingertips push with at least 15 N and the thumb with at least 10 N, and Inspire rates the passive payload at 30 kg.
- Closes in 0.8 s The four fingers flex at over 107°/s and the thumb rotates through 60–180° at over 155°/s, with fingertips repeating to ±0.2 mm.
Description
The Inspire RH56F1-E2R is the right hand of Inspire Robots' RH56F1 dexterous robotic hand, in the build without tactile sensors and with the E2 interface, EtherCAT plus RS-485. Ordered with the RH56F1 left hand (E2L), it completes a matched pair for a two-armed humanoid or a dual-arm research cell; on its own, it gives a single right arm five fingers where a parallel gripper runs out of options.
Six micro linear servo actuators move 12 joints: one actuator for each of the four fingers and two for the thumb, which bends and rotates laterally through 60–180°. The thumb rotates at more than 155°/s and flexes at more than 37°/s, the four fingers flex at more than 107°/s, and a full close takes 0.8 s or less. All of it sits in an all-metal integrated skeleton with the wiring routed inside; the hand weighs 620 g and measures 183.3 mm long by 79.1 mm across the palm.
Every actuator carries its own force sensor, read at 0.1 N resolution, and that is how the hand grips: give each finger a force threshold and it closes until it reaches that force or its target position. Force closed-loop and impedance modes are there for soft or fragile objects that must be held without being crushed. Fingertips push with at least 15 N and the thumb with at least 10 N, they repeat to ±0.2 mm, and Inspire rates the passive payload at 30 kg after putting the series through 20 stringent tests.
The E2 interface runs 1 kHz real-time communication over EtherCAT, or RS-485 with Inspire's open register protocol or Modbus RTU, and up to 254 hands can share one RS-485 bus. Power is 24–48 V with a 5 A peak at 24 V. The wrist has an 8-pin aviation connector and four 3.5 mm through holes for mounting; fitment to your arm or humanoid is confirmed with the quotation.
Need contact data as well as finger force? The RH56F1 tactile right hand (E2R-T1) adds eight capacitive tactile sensors in the fingertips and palm. For a stronger grip, the Inspire RH56E2 pushes 28 N per fingertip. See the whole range of dexterous robotic hands.
Key Capabilities
- Right hand with the E2 interface: The E2R mirrors the left-hand E2L and carries EtherCAT plus RS-485 with 1 kHz real-time communication.
- A force sensor on every actuator: Each of the six micro linear servo actuators reports force at 0.1 N resolution, so every finger can stop at a set force.
- Three grip control modes: Speed-force protection, force closed-loop and impedance control can be set finger by finger.
- Rigid metal frame at 620 g: An all-metal integrated skeleton with internal wiring keeps the hand at 620 g, 183.3 mm long and 79.1 mm across the palm.
- 15 N fingertips, 30 kg passive load: Fingertips push with at least 15 N and the thumb with at least 10 N, and Inspire rates the passive payload at 30 kg.
- Closes in 0.8 s: The four fingers flex at over 107°/s and the thumb rotates through 60–180° at over 155°/s, with fingertips repeating to ±0.2 mm.
Buying through Robotix Market
This unit is sourced new through established distribution channels and ships worldwide with the manufacturer warranty. Technical support is coordinated with the manufacturer's own service network. Deployment scope, configuration, and commissioning responsibilities are agreed as part of the quotation — on-site installation is not included in the product price.
Official Product Videos
Features
Specs
| Brand | Inspire Robots |
|---|---|
| Model | RH56F1-E2R |
| Hand side | Right |
| Version | E2 (EtherCAT + RS-485), without tactile sensors |
| Fingers | 5 |
| Degrees of freedom | 6 |
| Joints | 12 |
| Actuators | 6 micro linear servo actuators, each with a force sensor |
| Structure | All-metal integrated skeleton, concealed wiring |
| Weight | 620 ± 10 g |
| Length | 183.3 mm |
| Palm width | 79.1 mm |
| Fingertip strength | ≥ 15 N |
| Thumb fingertip strength | ≥ 10 N |
| Force resolution | 0.1 N |
| Passive payload | 30 kg |
| Repeatability | ±0.2 mm |
| Thumb lateral rotation range | 60–180° |
| Thumb lateral rotation speed | > 155°/s |
| Thumb flexion speed | > 37°/s |
| Four-finger flexion speed | > 107°/s |
| Hand closing time | ≤ 0.8 s |
| Finger control modes | Speed-force protection, force closed-loop, impedance control |
| Feedback per degree of freedom | Actuator position, angle, force, current, temperature, status and error codes |
| Control interface | EtherCAT + RS-485 |
| Protocols | Open register protocol and Modbus RTU over RS-485; EtherCAT PDO and SDO |
| Communication | 1 kHz real-time |
| Hands per RS-485 bus | Up to 254 |
| Operating voltage | 24–48 V |
| Quiescent current at 24 V | 194 ± 10 mA (RS-485), 210 ± 10 mA (EtherCAT) |
| Peak current | 5 A at 24 V |
| Tactile sensors | None (fitted on the RH56F1-E2R-T1) |
| Wrist connector | 8-pin aviation plug, compatible with LEMO FGG-1B-8P |
| Wrist mounting | 4 × Ø3.5 mm through holes |
| SDK and ROS support | Confirm at quote |
| Robot mounting | Confirm at quote |
Industries
Frequently Asked Questions
The Inspire RH56F1 Dexterous Hand Right (E2R) is priced at €4.120 in your market.
Yes, the E2R is the right hand. The RH56F1-E2L is the left hand with the same specification; one of each makes a matched pair, and on a shared RS-485 bus each hand takes its own ID.
Six, moving 12 joints. Each of the four fingers has one actuator, and the thumb has two: one to bend it and one to rotate it laterally through 60–180°.
The E2R grips by the six actuator force sensors at 0.1 N resolution and has no tactile sensors. The E2R-T1 adds eight capacitive tactile sensors, one in each fingertip and three in the palm, with a 30 N range and 5 % full-scale accuracy.
Each fingertip pushes with at least 15 N and the thumb with at least 10 N. Inspire rates the passive payload at 30 kg, and the hand itself weighs 620 g.
Over EtherCAT, or over RS-485 with Inspire's open register protocol or Modbus RTU, with 1 kHz real-time communication on a 24–48 V supply. Each finger runs speed-force protection, force closed-loop or impedance control; fitment to your arm or humanoid is confirmed with the quotation.