- Eight capacitive tactile sensors One sensor in each fingertip and three across the palm measure contact up to 30 N with 5 % full-scale accuracy.
- Force direction, not just pressure Fingertip and palm sensors report normal force, tangential force and its direction from 0 to 359°, in 0.01 N steps.
- Proximity at the fingertips Each fingertip sensor also returns a proximity value as the finger approaches a surface.
- Six force-sensing actuators Six micro linear servo actuators move 12 joints, and each reports finger force at 0.1 N resolution.
- 620 g all-metal right hand The hand is 183.3 mm long and 79.1 mm across the palm, pushes at least 15 N per fingertip and is rated for a 30 kg passive payload.
- EtherCAT and RS-485 at 1 kHz The E2 interface combines both buses with 1 kHz real-time communication on a 24–48 V supply.
Description
The Inspire RH56F1-E2R-T1 is the right-hand, tactile version of Inspire Robots' RH56F1 dexterous robotic hand: the same six-actuator, twelve-joint, all-metal hand as the RH56F1-E2R, with eight capacitive tactile sensors added in the fingertips and palm. It is the RH56F1 to choose when a robot has to feel where and how it touches an object, not only how hard each finger is pressing.
Each of the five fingertips carries a sensor that reports normal force, tangential force and the direction of that tangential force from 0 to 359°, plus a proximity value as the finger approaches a surface. Three more sensors cover the left, middle and right zones of the palm and report normal and tangential force with direction. The range is 30 N and the accuracy 5 % of full scale, with readings delivered in 0.01 N steps; tangential force and its direction are the readings a controller uses to detect slip.
The mechanics match the rest of the RH56F1 line. Six micro linear servo actuators, each with a force sensor at 0.1 N resolution, move 12 joints; fingertips push with at least 15 N and the thumb with at least 10 N, and they repeat to ±0.2 mm. The thumb rotates laterally through 60–180°, the hand closes in 0.8 s or less, and Inspire rates the passive payload at 30 kg. It weighs 620 g and is 183.3 mm long and 79.1 mm across the palm.
Tactile values come from their own registers next to each actuator's position, force, current and temperature, over the E2 interface: EtherCAT, or RS-485 with Inspire's open protocol or Modbus RTU, with 1 kHz real-time communication on a 24–48 V supply. Each finger can run speed-force protection, force closed-loop or impedance control. The wrist mounts on four 3.5 mm through holes, and fitment to your arm or humanoid is confirmed with the quotation.
For a two-handed robot, the RH56F1 tactile left hand (E2L-T1) is the mirror of this one. When finger force feedback is enough, the RH56F1 right hand without tactile sensors (E2R) has the same mechanics and interfaces. Compare the full range of dexterous robotic hands.
Key Capabilities
- Eight capacitive tactile sensors: One sensor in each fingertip and three across the palm measure contact up to 30 N with 5 % full-scale accuracy.
- Force direction, not just pressure: Fingertip and palm sensors report normal force, tangential force and its direction from 0 to 359°, in 0.01 N steps.
- Proximity at the fingertips: Each fingertip sensor also returns a proximity value as the finger approaches a surface.
- Six force-sensing actuators: Six micro linear servo actuators move 12 joints, and each reports finger force at 0.1 N resolution.
- 620 g all-metal right hand: The hand is 183.3 mm long and 79.1 mm across the palm, pushes at least 15 N per fingertip and is rated for a 30 kg passive payload.
- EtherCAT and RS-485 at 1 kHz: The E2 interface combines both buses with 1 kHz real-time communication on a 24–48 V supply.
Buying through Robotix Market
This unit is sourced new through established distribution channels and ships worldwide with the manufacturer warranty. Technical support is coordinated with the manufacturer's own service network. Deployment scope, configuration, and commissioning responsibilities are agreed as part of the quotation — on-site installation is not included in the product price.
Official Product Videos
Features
Specs
| Brand | Inspire Robots |
|---|---|
| Model | RH56F1-E2R-T1 |
| Hand side | Right |
| Version | E2 (EtherCAT + RS-485) with T1 tactile sensors |
| Fingers | 5 |
| Degrees of freedom | 6 |
| Joints | 12 |
| Actuators | 6 micro linear servo actuators, each with a force sensor |
| Structure | All-metal integrated skeleton, concealed wiring |
| Weight | 620 ± 10 g |
| Length | 183.3 mm |
| Palm width | 79.1 mm |
| Tactile sensors | 8 capacitive: one in each fingertip, three in the palm (left, middle and right zones) |
| Tactile measurements | Normal force, tangential force and tangential force direction (0–359°); proximity at each fingertip |
| Tactile range | 30 N |
| Tactile accuracy | 5 % of full scale |
| Tactile data resolution | 0.01 N |
| Fingertip strength | ≥ 15 N |
| Thumb fingertip strength | ≥ 10 N |
| Force resolution (actuator sensors) | 0.1 N |
| Passive payload | 30 kg |
| Repeatability | ±0.2 mm |
| Thumb lateral rotation range | 60–180° |
| Thumb lateral rotation speed | > 155°/s |
| Thumb flexion speed | > 37°/s |
| Four-finger flexion speed | > 107°/s |
| Hand closing time | ≤ 0.8 s |
| Finger control modes | Speed-force protection, force closed-loop, impedance control |
| Control interface | EtherCAT + RS-485 |
| Protocols | Open register protocol and Modbus RTU over RS-485; EtherCAT PDO and SDO |
| Communication | 1 kHz real-time |
| Operating voltage | 24–48 V |
| Quiescent current at 24 V | 194 ± 10 mA (RS-485), 210 ± 10 mA (EtherCAT) |
| Peak current | 5 A at 24 V |
| Wrist connector | 8-pin aviation plug, compatible with LEMO FGG-1B-8P |
| Wrist mounting | 4 × Ø3.5 mm through holes |
| SDK and ROS support | Confirm at quote |
| Robot mounting | Confirm at quote |
Industries
Frequently Asked Questions
The Inspire RH56F1 Tactile Dexterous Hand Right (E2R-T1) is priced at €5.775 in your market.
Eight capacitive tactile sensors: one in each of the five fingertips and three in the palm. Everything else, from the 6 degrees of freedom to the 620 g weight and the EtherCAT and RS-485 interface, is the same as on the RH56F1-E2R.
Normal force, tangential force and the direction of the tangential force from 0 to 359°, with a 30 N range and 5 % full-scale accuracy. The fingertip sensors also report proximity.
Six, moving 12 joints. The four fingers have one actuator each and the thumb two, for bending and for lateral rotation through 60–180°.
Over EtherCAT, or over RS-485 with Inspire's open register protocol or Modbus RTU, with 1 kHz real-time communication. It runs on 24–48 V with a 5 A peak at 24 V; fitment to your robot is confirmed with the quotation.
Yes, this is the right hand. The RH56F1-E2L-T1 is the left hand with the same eight tactile sensors, so the two make a tactile pair for a two-armed robot.
Inspire RH56F1 Tactile Dexterous Hand Right (E2R-T1)
- Regular price
- €5.775,00
- Sale price
Recently Viewed
You haven't viewed any products yet.